新    詢 價 / 訂  

溫/濕/光度/CO2 記錄器 (12-bits)

HOBO® U12 Indoor Data Logger Family

12-bit loggers with USB interface

New HOBO U12 Family data loggers offer reliability and convenient monitoring for applications that require higher accuracy, better resolution, more memory or USB connectivity for fast data readout to your PC. Operation of U12 Family data loggers requires Onset’s easy-to-use GreenLine® software (Windows) or HOBOware™ software (Mac) software for logger launch, offload, and data viewing.

HOBO U12 Temp Data Logger HOBO U12 Temp/RH Data Logger
HOBO U12 Temp/RH/Light/External Data Logger
HOBO U12 Temp/RH/2 External Data Logger

U12-001
Temp

U12-006- NEW
4 External Channels

•AC Current

•4-20mA

•DC Voltage

•Temp

•CO2

U12-011
Temp/RH

U12-012
Temp/RH/
Light/
External Channels
•AC Current
•4-20mA
•DC Voltage
•Temp
•CO2

U12-013
Temp/RH
2 External Channels

•AC Current

•4-20mA

•DC Voltage

•Temp

•CO2

 

 

Required Software

 

Features and specifications

  • 12-bit resolution
  • 43,000 12-bit measurements
  • Complete download in 30 seconds via direct USB interface
  • Programmable start time/date or push-button start
  • Programmable sampling rate (1 second to 18 hours)
  • Numerous event types (button push/release, host PC connection, low battery), stored to data file asynchronously during logging
  • Battery level indication at launch
  • Battery level can be recorded as a separate channel
  • Blinking LED confirms operation
  • 1-year battery life (typical) – user-replaceable CR-2032 lithium battery
  • Non-volatile memory retains data even if battery fails
  • NIST-traceable temperature accuracy certification available
  • Operating Range: -20° to 70°C (-4° to 158°F), 5% to 95% RH non-condensing, non-fogging
  • Size/Weight: 5.8 x 7.4 x 2.2 cm (2.3 x 2.9 x 0.85")/approx. 46 gms (1.6 oz.)
HOBO U12 Temperature Data Logger
Part # U12-001
Single channel USB temperature logger with 12-bit resolution.
Key Specifications
Measurement Range: -20° to 70°C (-4° to 158°F)
Accuracy: ±0.35°C from 0° to 50°C (±0.63°F from 32° to 122°F)
HOBO U12 4 External Channel Data Logger
Part # U12-006
4 external input channels accept a wide range of external sensors and cables for temperature, CO2, AC Current, 4-20mA, and DC Voltage. (See External Sensor) Requires GreenLine version 1.1.
Key Specifications
External Input Channel Measurement Range (See External Sensor): 0 to 2.5 DC Volts
Accuracy: ± 2mV ± 2.5% of absolute reading
HOBO U12 Temp/RH Data Logger
Part # U12-011
Two-channel USB temperature/relative humidity logger with high-accuracy internal sensors, direct USB interface and 12-bit resolution.
Key Specifications
Temperature Measurement Range: -20° to 70°C (-4° to 158°F)
Accuracy: ± 0.35°C from 0° to 50°C (± 0.63°F from 32° to 122°F)
Relative Humidity Measurement Range: 5% to 95% RH
Accuracy: ± 2.5% RH from 10% to 90% typical
HOBO U12 Temp/RH/Light/External Channel Data Logger
Part # U12-012
Four-channel 12-bit USB logger provides high-accuracy temperature, relative humidity and relative indoor light level measurements. Versatile external channel accepts a wide range of external sensors and input cables for temperature, CO2, AC Current, 4-20mA, and DC Voltage. (See External Sensor).
Key Specifications
Temperature Measurement Range (internal sensor): -20° to 70°C (-4° to 158°F)
Accuracy: ± 0.35°C from 0° to 50°C (± 0.63°F from 32° to 122°F)
Relative Humidity Measurement Range (internal sensor): 5% to 95% RH
Accuracy: ± 2.5% RH from 10% to 90% typical
Light Intensity Measurement Range (internal sensor): 1 to 3000 footcandles (lumens/ft2) typical
External Input Channel Measurement Range (See External Sensor)
Accuracy: ± 2mV ± 2.5% of absolute reading
HOBO U12 Temp/RH/2 External Channel Data Logger
Part # U12-013
Versatile four-channel 12-bit USB logger has high-accuracy temperature and relative humidity sensors. Two external channels accept a wide range of external sensors and input cables for temperature, CO2, AC Current, 4-20mA, and DC Voltage. (See External Sensor).
Key Specifications
Temperature Measurement Range (internal sensor): -20° to 70°C (-4° to 158°F)
Accuracy: ± 0.35°C from 0° to 50°C (± 0.63°F from 32° to 122°F)
Relative Humidity Measurement Range (internal sensor): 5% to 95% RH
Accuracy: ± 2.5% RH from 10% to 90% typical
External Input Channel Measurement Range (See External Sensor): 0 to 2.5 DC Volts
Accuracy: ± 2mV ± 2.5% of absolute reading

 


Telaire 7001 CO2 Sensor (requires CABLE-CO2 to connect to H8 and U12 loggers)

* Note: Not for use with Intrinsically Safe (IS) loggers

 


CO2 Sensor to Logger Cable (CABLE-CO2)*


CO2 Sensor,     室外 溫度/濕度 V2     HOBO 記錄器  各式 data logger